Learn / Clinical Research Management / Conducting the trial at the site
Source documents and data integrity
13 minute read · 6-question quiz
What you will learn
Define source data, source documents and the case report form
Apply the ALCOA+ principles to records
Correct records properly and avoid common documentation errors
Trial results are only as good as the records behind them. GCP requires that data be reliable, accurate and verifiable.
Key terms
- Source data: the original records of clinical findings, observations and activities needed to reconstruct and evaluate the trial.
- Source documents: the places where source data are first recorded: hospital records, clinic notes, laboratory reports, diaries, instrument printouts, pharmacy records, and electronic records.
- Case report form (CRF): the document (paper or electronic) in which data required by the protocol are collected for each participant.
- Source data verification (SDV): the process in which the CRA compares CRF entries with source documents.
When a CRF entry is the first place a value is recorded, the CRF itself is the source, and this should be stated in the protocol or a source data agreement.
ALCOA+
Good records follow the ALCOA principles, extended to ALCOA+.
- Attributable: who recorded the data and when.
- Legible: readable, permanently.
- Contemporaneous: recorded at the time of the observation.
- Original: the first record, or a certified copy.
- Accurate: correct and error-free.
- + Complete, Consistent, Enduring and Available.
How to correct an error
On paper, draw a single line through the entry so it stays legible, write the correct value, then initial, date and give a reason if not obvious. Never use correction fluid, erase or overwrite. In electronic systems, changes are made through an audit trail that records who, when and why.
Common documentation problems
- Late entries without a note explaining the delay.
- Missing signatures or dates.
- Unexplained discrepancies between source and CRF.
- Pre-filled or "back-filled" data.
- Missing records of test results reviewed by the investigator.
- Photocopies without certification when originals are needed.
Summary
Source data are original records; CRFs collect protocol-required data; SDV compares the two.
ALCOA+ describes trustworthy records: attributable, legible, contemporaneous, original, accurate, complete, consistent, enduring and available.
Corrections keep the original visible with initials, date and reason; electronic systems use audit trails.
Fabrication and back-dating are misconduct.
Check your understanding
Draft study guide. Spotted an error or something unclear? Tell us at hello@scintria.com. This is educational material, not clinical or regulatory advice.